Anyone who works with ISO/SAE 21434 and the TARA as a cyber risk assessment method in vehicle development brings more to rail projects than they think, but less than they hope. In this article we look at which cybersecurity standards apply in the rail industry, how the technical terms of the automotive and rail worlds relate to each other, and the five places where a direct transfer fails. All aboard.
Gnanagiri Balasubramanian
More and more suppliers, engineering service providers, consultancies, and project teams from the automotive and vehicle industry are also working on rail vehicles.
The technology used there looks familiar at first: networked control units, Ethernet backbones, remote access for diagnostics and maintenance, software updates over the entire service life.
So the obvious question is whether the security engineering practice built up over years in vehicle development can simply be taken along. Anyone already familiar with the basics of automotive cybersecurity now needs to find out where and how these can be applied to rail projects. That includes project leads and managers who are not technical security specialists but still plan effort, responsibilities, and evidence for cybersecurity.
Our focus here is on the vehicle (rolling stock). Signaling and infrastructure are touched on only where they meet the system boundary of the vehicle.
On the overarching question of how far vehicle security practice carries over to cybersecurity in the rail industry, here is a rough orientation before we go into detail:
- Mindset yes, method no. The logic that runs from threat to consequence to decision holds. The assessment criteria and result metrics established in vehicle development do not.
- From asset to zone. Automotive assesses risks per asset and damage scenario. Rail divides the system into zones and sets a security level for each.
- Security feeds safety. In rail, the safety case is a process of its own, and cybersecurity contributes to it. (In this article we already looked at how security and safety risk assessment interact in automotive)
What does that mean in concrete terms?
Cybersecurity for Rail: Why the Topic Is Now on the Table (and Within Closer Reach)
In automotive, type approval drives the topic: without CSMS evidence under UN R155, no new vehicles have been registered since 2024. Rail has no counterpart of this kind so far. The pressure there comes from two other directions:
- Cybersecurity and information security requirements for operators. In the EU, railway undertakings and infrastructure managers fall under NIS2. In Germany this has applied since December 6, 2025, through the NIS2 Implementation Act, which recasts the BSI Act; rail transport belongs to the transport and traffic sector there. Operators must secure their supply chain and pass this obligation on to vehicle manufacturers and suppliers through requirement specifications and contracts. Comparable requirements for rail operators exist outside the EU as well, for example through the TSA Security Directives in the United States.
- Cybersecurity in product law. Road vehicles within the scope of Regulation (EU) 2019/2144 are exempt from the Cyber Resilience Act (CRA); rail products are not. For manufacturers this means two things. The CRA reporting obligations have applied since September 11, 2026, including for products already on the market. From December 11, 2027, every product with digital elements placed on the market for the first time must be CRA compliant, in the rail sector too. (How this is to be interpreted for vehicles with long project durations is still under discussion in the industry. The associations CER, UITP, and UNIFE published an implementation guide on this in April 2026.)
For people moving over from automotive, this yields an important planning factor: in a rail project, requirements come from the operator contract and from product law, rarely from a single approval regulation.
The Railway Cybersecurity Standards at a Glance
We assume here that ISO/SAE 21434:2021 is known as the most important industry standard for cybersecurity engineering in vehicle development. So what follows is only a brief look at its method for assessing cyber risks, the TARA.
The TARA according to Clause 15 follows a fixed chain:
- Assets and damage scenarios
- Threat scenarios
- Impact rating in the categories safety, financial, operational, and privacy
- Attack paths
- Attack feasibility
- Risk value
- Risk treatment decision
The result is cybersecurity goals or claims, from which requirements are derived in the concept. The object of analysis is the item, that is, a function at vehicle level together with its components.
IEC 62443, CLC/TS 50701, and IEC 63452
Unlike the automotive industry, rail has not developed a cyber risk assessment method of its own. It has adopted and adapted the IEC 62443 series from industrial automation.
There are three documents you should know:
- IEC 62443-3-2 describes risk assessment at system level. It runs in two passes. First, the system under consideration (SuC) is delimited and assessed at a high level. Then it is partitioned into zones and conduits. For each zone and each conduit a detailed risk assessment follows, which ends in a target security level and the associated requirements.
- CLC/TS 50701 is the European Technical Specification for the rail sector, currently in its 2023 edition. It derives its models, concepts, and risk process from the IEC 62443 series and places cybersecurity management within the RAMS life cycle of EN 50126-1. That is why it is the working document in European vehicle projects today: it speaks the language in which rail projects are organized anyway.
- IEC 63452 turns this approach into an international standard. As of November 2026 it is available as a final draft: the vote on the FDIS runs from October 30 to December 11, 2026. According to the IEC, it covers management, zoning, risk management, supply chain, requirements, assurance, and operation, maintenance, and decommissioning. Anyone starting a project today will usually still work to TS 50701, but should plan for the replacement and clarify in contracts which standard applies in which edition.
Automotive Cybersecurity vs. Railway Cybersecurity: Translating the Key Terms
In practice, many misunderstandings in interdisciplinary teams arise because similar things have different names and different things sound similar.
The following mapping is a first overview, not a legally reliable classification of formal equivalents.
| Automotive (ISO/SAE 21434) | Railway (IEC 62443 / TS 50701) | What to watch for |
| Item, item definition | System under consideration (SuC) | The SuC is delimited by operation and by interfaces to the overall rail system |
| Asset with security properties | Assets within zones | Protection needs are assigned to the zone |
| Damage scenario, impact rating | Consequences, assessed by the operator’s criteria | No uniform four-category scale |
| Threat scenario | Entry in the threat log per zone and conduit | Same mindset, different reference |
| Attack feasibility | Likelihood, assumptions about attacker capability | Attacker capability is also built into the security level |
| Risk value (1 to 5) | Risk compared with tolerable risk | Risk value and SL-T cannot be converted into each other |
| Cybersecurity goal | SL-T per zone and conduit plus requirements | The result is a security level, not an individual goal |
| Cybersecurity claim | Assumptions, security-related application conditions | Conditions are passed on to the operator and to safety |
| CAL (optional) | No direct counterpart | CAL is not the same as SL |
| OEM, Tier 1, Tier 2 | Operator, system integrator, product supplier | The vehicle manufacturer is usually the integrator; the operator is the customer and defines risk acceptance |
| Cybersecurity case | Cybersecurity case | Is interlinked with the safety case |
Security Level: The Central Concept of Railway Security
The security level (SL) comes from IEC 62443, so it is not a rail-specific concept. For people moving over from automotive, though, it is new and deserves a closer explanation.
What does a security level (SL) say in railway cybersecurity? An SL describes the kind of attacker a zone is meant to be protected against. The levels run from 0 (no particular requirements) to 4:
- SL 1: protection against casual or coincidental violation
- SL 2: protection against intentional attacks using simple means, low resources, generic skills, and low motivation
- SL 3: protection against intentional attacks using sophisticated means, moderate resources, system-specific skills, and moderate motivation
- SL 4: protection against intentional attacks using sophisticated means, extended resources, system-specific skills, and high motivation
Anyone who knows the attack potential approach of ISO/SAE 21434 will recognize the kinship: the attacker’s expertise, equipment, and resources appear in both worlds. The difference lies in the direction. Attack feasibility rates how easy a particular attack path is. The security level defines which attacker the system is meant to withstand.
Why an SL is a vector. IEC 62443 groups protection requirements into seven foundational requirements (FR): identification and authentication control, use control, system integrity, data confidentiality, restricted data flow, timely response to events, and resource availability. A security level is assigned per FR. A zone may need SL 3 for authentication and SL 1 for confidentiality. This differentiation prevents a single high value from pulling all measures up across the board.
Three types of security level. The standard distinguishes who sets the value and what it means:
- SL-T (target): the target security level of a zone or conduit, the result of the risk assessment
- SL-C (capability): the security level a component or system can reach when configured correctly, demonstrated by the supplier
- SL-A (achieved): the level actually achieved in the real, integrated system
This three-way split determines the division of work in the project. The integrator derives SL-T and looks for components whose SL-C matches. Where a component falls short, compensating countermeasures in the architecture are needed. The concrete requirements per level are in IEC 62443-3-3 for systems and in IEC 62443-4-2 for components. For suppliers, SL-C according to 4-2 is therefore the figure customers will ask for.
What a security level is not. An SL-T is not a risk value and not a CAL. A risk value of 4 in an automotive TARA therefore says nothing about whether a zone needs SL 2 or SL 3. Important: anyone who wants to reuse existing assessments needs a documented rationale and a new assessment against the criteria of the rail project.
What Carries Over From the Automotive TARA to Railway Cybersecurity
Teams with ISO/SAE 21434 experience bring trained people, practiced workflows, and often existing security work products. What carries over is above all the way of working.
The following overview shows what the individual TARA building blocks contribute in a rail project and what has to be defined anew:
| TARA building block | Benefit in the rail project | What has to be defined anew |
| Item definition | Structured description of functions, boundaries, interfaces | SuC according to the rail process, including operational dependencies |
| Damage scenarios | Link between technical compromise and real-world consequence | Rail-specific operational consequences |
| Impact rating | Discipline in assessing consequences | The operator’s criteria and scales |
| Threat scenarios, attack paths | Systematic thinking from the attacker’s point of view, for example with STRIDE | Threat log per zone and conduit |
| Attack feasibility | Traceable estimate of the effort required | Access conditions and attacker model of the railway |
| Risk treatment | Documented, justified decisions | Risk acceptance by the operator |
| Goals and requirements | Continuous chain from risk to requirement | Allocation to zones, conduits, and SL-T |
Audits in the automotive and vehicle industry have shown in recent years that the greatest value lies in traceability.
A team that is used to tracing every requirement back to a risk and following it through to verification has a real head start in a rail project.
Railway Cybersecurity in Practice: Remote Maintenance Access on a Multiple-Unit Train
An example makes the process outlined so far tangible. Its main purpose is to demonstrate three work steps that do not exist in this form in the TARA: zoning, deriving the target security level, and passing conditions on to the operator.
The Starting Point
A vehicle manufacturer delivers a multiple-unit train with remote maintenance access to a rail operator: the train is connected to the manufacturer’s maintenance system over a cellular network. This makes the manufacturer the system integrator and the rail company the operator. Four elements matter for the example:
- Train control (TCMS). The train control and management system is the train’s central control and diagnostics network. Among other things, it connects traction and brake control, doors, and air conditioning. In a passenger car, the closest equivalent would be the combination of central computers and domain control units.
- Maintenance gateway. An onboard computer with a cellular modem through which the train can be reached from outside.
- Ground-side maintenance system. The manufacturer’s servers, where maintenance technicians work.
- Passenger systems. Passenger information and passenger Wi-Fi, which run on the same train.
Through remote maintenance, technicians from the manufacturer or a service provider regularly read out diagnostic data. In defined cases they also load configurations. The automotive counterpart would be diagnostic access via the backend.
What Works as Usual
The start is familiar to anyone with TARA experience. The system under consideration (SuC) is delimited like an item, with one addition: what sits at the other end is part of it, that is, the workshop network, fleet management, and the operator’s systems. Next, the consequences of a compromise are named, just like damage scenarios in the TARA: vehicles are out of service, diagnostics are unavailable, a vehicle runs with a wrong configuration, neighboring systems become reachable. The assessment follows the operator’s criteria, in which operational availability usually weighs more heavily than in a passenger car. Threat analysis and end-to-end traceability from requirement to risk also work as you know them.
The following three steps are new:
New: Partitioning the System Into Zones and Conduits
A zone groups systems that need the same protection. A conduit is the connection between two zones, that is, the path over which data crosses the zone boundary. Threats are then recorded per zone and per conduit, not per asset.
For the multiple unit, this partitioning would be plausible:
- Zone A: train control with traction and brake control
- Zone B: maintenance gateway as a buffer zone
- Zone C: passenger information and passenger Wi-Fi
- Zone D: ground-side maintenance system
- Conduit 1: cellular link between B and D
- Conduit 2: transition between B and A
- Conduit 3: data flow from A to C, in this direction only (for example, to display the next stop)
Zoning forces two architecture decisions early on. Remote access ends in Zone B and reaches train control only through a controlled transition. And the passenger systems, which every traveler reaches with their own device, cannot write anything back into train control.
New: From Risk to Target Security Level
For each zone and each conduit, the manufacturer defines an SL-T (see the explanations above), which the operator approves. Conduit 1 serves to show how the values come about. They are illustrative and not prescribed by any standard.
The first question is about the attacker. The link runs over a public cellular network and can be reached remotely. Manufacturer and operator therefore assume a deliberately acting attacker with system knowledge and moderate resources. That corresponds to level 3.
Then each requirement is checked to see whether this level is needed. The decisive factor is the most severe consequence, here a vehicle running with a configuration that was changed without authorization:
| Requirement | SL-T | Rationale |
| Identification and authentication control | 3 | Only authorized technicians and systems may establish the connection |
| Use control | 3 | Reading and writing are authorized separately; writing requires approval |
| System integrity | 3 | A configuration must not be altered in transit |
| Restricted data flow | 3 | The connection ends at the gateway, with no pass-through to train control |
| Data confidentiality | 2 | Diagnostic data is not very sensitive; credentials must be protected |
| Timely response to events | 2 | Access is logged and evaluated; an immediate response is not required |
| Resource availability | 2 | If remote maintenance fails, the train keeps running; diagnostics take place in the workshop |
That leaves the question of why not SL 4. A changed configuration could affect safety-relevant functions only if it reached Zone A. The transition there is a separate, controlled conduit, and write access is tied to operating conditions (see below). The architecture therefore already limits the consequences before the security level of the radio link comes into play.
From the vector, IEC 62443-3-3 yields concrete requirements, such as multifactor authentication for access from untrusted networks. The manufacturer then looks for a gateway whose SL-C matches. If it falls short at any point, compensating countermeasures in the architecture are needed.
New: Passing Conditions On to the Operator
The manufacturer cannot ensure some of the assumptions of the assessment itself, because they have to be met in operation. Rail calls them security-related application conditions (SecRAC). They are the counterpart to the safety-related application conditions that rail projects know from safety. In the example there would be two:
- Remote write access is permitted only at standstill and after approval by the operator.
- Access accounts of technicians who have left are disabled within a defined period.
These conditions go to the operator. Because the first one also protects safety-relevant functions, it additionally goes to the safety team, which takes it into account in its safety case.
Anyone who knows vertical TARA integration from vehicle development will recognize the pattern. There, the supplier passes damage scenarios together with assumptions upward, and the OEM passes requirements downward. In rail, this exchange is built into the standards: the target security level goes to the supplier, whose component answers with its SL-C, and the assumptions travel on as SecRAC all the way to the operator. What is exchanged is not scenarios, then, but security levels and conditions.
Five Places Where a Direct Transfer From Automotive to Railway Security Fails
The example already shows how far TARA experience carries: system description, thinking in consequences, threat analysis, and traceability can be used almost unchanged.
It also shows where the process departs from what you are used to, for example in zoning, in the SL-T, and in the conditions that go to the operator.
Behind these departures are five fundamental differences between the two worlds. Anyone who knows them can check existing templates, scales, and prior assessments in a targeted way, instead of adopting them unchecked or rejecting them wholesale.
1. The System Boundary
A passenger car is a largely self-contained product with defined external interfaces. A rail vehicle is part of a system made up of vehicles, signaling, control centers, power supply, and maintenance. Train protection such as ETCS is installed on board, but in technical and regulatory terms it belongs to control-command and signaling and is subject to its own requirements. The boundary of the SuC therefore has to be drawn anew in every project, together with the operator.
2. The Risk Method
Automotive combines impact and attack feasibility into a risk value per threat scenario. Rail compares the risk per zone with a tolerable risk and derives SL-T from that. Tables, scales, and thresholds from automotive templates cannot be reused without justifying them anew on technical grounds.
3. The Role of Architecture
In the TARA, the architecture view emerges through attack paths. In rail, zoning is itself a work product and the prerequisite for everything that follows. Without a sound network and communication architecture, no zone can be formed. Projects that start with a template TARA before the architecture is in place do the work twice.
4. The Interface to Safety
In both industries, safety and security are separate disciplines. In automotive, hazard analysis follows ISO 26262, and the TARA considers safety as one of four impact categories. In rail, the separation is more formal: the safety case according to the CENELEC standards (EN 50126 for the RAMS process, EN 50129 for safety-related electronics in signaling, EN 50716 for software) is a central building block of authorization, and security acts on it as an external influence. TS 50701 regulates the cooperation explicitly, among other things with a dedicated section on security-related application conditions. The upcoming IEC 63452 keeps to this line: it sets no safety requirements but gives guidance on the relationship between the two processes. In practice this means that an SL-T is no evidence of safety, and security patches on authorized systems need a coordinated change process.
5. Roles and Product Lifecycle
The automotive value chain of OEM, Tier 1, Tier n does not fit rail. There, operator, system integrator, and product supplier face each other, and the operator determines which risk is acceptable. IEC 63452 frames this as the goal of bringing risks to a level that is tolerable for the responsible operator (duty holder). Every operator can bring its own criteria, zone models, and evidence requirements.
Then there is the service life. Rail vehicles are often in service for 30 to 40 years, with several modernizations. Cryptography, operating systems, and communication technology become obsolete several times over in that period. Vulnerability management, update capability, and the question of who is responsible for what after the warranty ends therefore belong in the bid phase.
- Rail has not developed a TARA of its own. It works with IEC 62443-3-2 and CLC/TS 50701, and with IEC 63452 in the future.
- What gets assessed are the zones and conduits of a system, not the individual assets of an item.
- The risk assessment ends in a target security level per zone, not in a risk value or a cybersecurity goal.
- A security level describes the attacker a zone is meant to withstand and cannot be converted into a risk value, a CAL, or a SIL.
- The operator decides on the tolerable risk, while the vehicle manufacturer acts as system integrator.
- Anything that can only be ensured in operation goes to the operator as SecRAC and into the safety case.
- System definition, thinking in consequences, threat analysis, and traceability carry over directly from the TARA.
- The pressure comes from NIS2, operator contracts, and the CRA, not from a type approval as with UN R155.
- Key Learnings
Railway Cybersecurity From a Vehicle Security Perspective: Summary
Experience from automotive cybersecurity is an advantage in a rail project when it is understood as a way of working and not as a set of templates. Anyone who has mastered the logic of the TARA (see also our free ISO/SAE 21434 TARA video course) does not have to learn to think differently in the rail environment, but to classify differently: other system boundaries, other target metrics, other responsible parties.
Five points can be noted for planning:
- Clarify the standards: IEC 62443-3-2 provides the process, CLC/TS 50701 the rail adaptation, and IEC 63452 is about to be published. Specify in the contract which edition applies.
- Start with the architecture: architecture and zoning come before the detailed threat analysis.
- Read security levels correctly: SL-T is the target, SL-C the capability of the component, SL-A what has been achieved. None of them corresponds to an automotive risk value.
- Involve the operator early: risk acceptance, assessment criteria, and SecRAC are defined jointly.
- Price in the lifecycle: decades of operation, updates, and vulnerability handling are part of the bid.
Given the ongoing digitalization of rail, there is a strong case for building railway cybersecurity competence now. Rail is moving from operator-specific specifications toward uniform requirements. IEC 63452 creates an international reference. The European Union Agency for Railways (ERA) plans to address cybersecurity in the upcoming TSI revisions and to include minimum requirements in the TSI for control-command and signaling. In 2026, Europe’s Rail also released cybersecurity specifications in version 1.1 that reach down to component level and so far mainly target control-command and signaling; two of them are considered candidates for a later reference in the TSIs.
This brings closer what automotive teams know from UN R155: binding, verifiable requirements as part of authorization.
Standards and additional sources
- ISO/SAE 21434:2021, Road vehicles – Cybersecurity engineering
- IEC 62443-3-2:2020, Security risk assessment for system design
- IEC 62443-3-3:2013, System security requirements and security levels
- IEC 62443-4-2:2019, Technical security requirements for IACS components
- CLC/TS 50701:2023, Railway applications – Cybersecurity
- IEC 63452 (FDIS, Abstimmung bis 11.12.2026), Railway applications – Cybersecurity
- EN 50126-1:2017, RAMS – Generic RAMS process
- EN 50129:2018, Safety related electronic systems for signalling
- EN 50716:2023, Requirements for software development
- UN Regulierung Nr 155 – CSMS
- Richtlinie (EU) 2022/2555 (NIS2) und Verordnung (EU) 2024/2847 (CRA)